While the existing protocol has served Zeta Alarm Systems well for many years, it is a dated protocol, which has. As a company who invests heavily in the development of our products we made a decision in 2011 to design a brand new addressable protocol which we have named the Fyreye MKII Protocol. MKII Soft & Hard Addressable Fire Alarm System.

Addressable Fire Alarm System Design Install A Single
Dual-state fire detectors which can be programmed to give different modes of detection at different times of the day Its innovative design combines optimal protection with the highest levels of wearing comfort. Lightweight universal helmet for fire and rescue services. Pre- alarm function to minimise false alarms and the associated costs/inconvenience of an evacuationFor example, we install a single panel with a detector and sounder for a small commercial customer, through to a fully addressable fire alarm system for a.This Pocket Design & Installation booklet provides a simple guide for the provision of a fire detection and alarm system in accordance with the recommendations detailed within the British Standard Code of Practice BS5839-1:2002+A2:2008 The handbook is designed to act as an aide-memoire and there is no substitute for reading.

Addressable Fire Alarm System Design Manual Call Points
No equipment supplied by other manufacturers is expected to be compatible with such systems so the protocol used is said to be “closed”.Because the use of a closed protocol system can put the end user at a serious disadvantage in the event of subsequent problems with the equipment or manufacturer, a number of manufacturers produce the Detection and other devices only and have developed partnerships with independent manufacturers of control panels. These companies have no need to disclose the nature of their protocol to anyone, since they offer all the elements needed to provide an intelligent system. These neat and compact units are installed in strategic positions in large multi-storey/extensive buildings to reduce the travel time to obtain system information.The Fixfire® range of manual call points, detectors and alarm sounders utilise patented technology and are renowned for consistent and reliable operation.Open or Closed Protocol – What does it mean?It is most important to understand the difference between “Open” and “Closed” protocol fire alarm systems.In the Fire Detection industry, addressable systems use Control Panels and Detectors and other devices which communicate with each other by means of a protocol.Some manufacturers offer both Panels and Detectors. Manual call points/ fire detectors/ sounders.For larger systems, control panels are networked giving the potential for thousands of devices on one system.Repeater control panels are available to mimic information from the main control panel.
Since all details of the protocol are disclosed, it is referred to as an “open” protocol.Fixfire ® has always offered “open” protocol systems – we engender loyalty and strong lasting relationships for all the good reasons – not because our clients are tied!